Prevention of Mist Formation in Amine Based Carbon Capture: Field Testing Using a Wet ElectroStatic Precipitator (WESP) and a Gas-Gas Heater (GGH) - Université de Pau et des Pays de l'Adour Accéder directement au contenu
Article Dans Une Revue Energy Procedia Année : 2017

Prevention of Mist Formation in Amine Based Carbon Capture: Field Testing Using a Wet ElectroStatic Precipitator (WESP) and a Gas-Gas Heater (GGH)

Jan Mertens
  • Fonction : Auteur
P. Khakharia
  • Fonction : Auteur
Pieter Rogiers
  • Fonction : Auteur
J. Blondeau
  • Fonction : Auteur
H. Lepaumier
  • Fonction : Auteur
E. Goetheer
  • Fonction : Auteur
B. Schallert
  • Fonction : Auteur
K. Schaber
  • Fonction : Auteur

Résumé

This study presents the results of two field tests that aimed at evaluating two countermeasures (WESP and GGH) to avoid acid mist formation. A WESP is shown to be very efficient for the removal of nuclei from the flue gas (100 % efficient) and thus can prevent aerosol formation inside an amine based absorber. This is however only valid in the absence of SO2 in the flue gas entering the WESP. A decreasing WESP efficiency is noted in the presence of SO2 with increasing voltages as a result of newly formed aerosols inside the WESP. This implies that no or very low levels of SO2 should be present in the flue gas entering the WESP. Since most of the amine carbon capture installations have a pre-scrubber (usually using NaOH to remove residual SO2 in the flue gas leaving the power plant's Flue Gas Desulphurisation) in front of their amine absorber, the WESP must be installed behind this pre-scrubber and not in front of it. Having a Gas-Gas Heater (or any type of flue gas cooling such as a Low Temperature Heat Exchanger) installed upstream of the wet scrubbing may prevent homogenous nucleation and thus prevent the conversion of H2SO4 into sulfuric acid aerosols and consequently mist formation issues in the amine based carbon capture installation. Which option to choose amongst the two countermeasures presented in this study will depend on whether a new built installation is being considered or whether a carbon capture is planned as a retrofit into an existing installation.
Fichier principal
Vignette du fichier
2017_mertens.pdf (416.66 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-02888433 , version 1 (03-07-2020)

Identifiants

Citer

Jan Mertens, P. Khakharia, Pieter Rogiers, J. Blondeau, H. Lepaumier, et al.. Prevention of Mist Formation in Amine Based Carbon Capture: Field Testing Using a Wet ElectroStatic Precipitator (WESP) and a Gas-Gas Heater (GGH). Energy Procedia, 2017, 114, pp.987-999. ⟨10.1016/j.egypro.2017.03.1244⟩. ⟨hal-02888433⟩
52 Consultations
148 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More