Simultaneous speciation analysis of Sb(III), Sb(V) and (CH 3)3SbCl2 by high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry detection (HPLC-HG-AFS): Application to antimony speciation in sea water - Université de Pau et des Pays de l'Adour Accéder directement au contenu
Article Dans Une Revue Journal of Chromatography A Année : 2005

Simultaneous speciation analysis of Sb(III), Sb(V) and (CH 3)3SbCl2 by high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry detection (HPLC-HG-AFS): Application to antimony speciation in sea water

Résumé

This paper presents an improvement for the simultaneous separation of Sb(V), Sb(III) and (CH3)3SbCl2 species by high performance liquid chromatography (HPLC) and its detection by hydride generation-atomic fluorescence spectrometry (HG-AFS). The separation was performed on an anion exchange column PRP-X100 using a gradient elution program between EDTA/KHP (potasium hydrogen phtalate) as first mobile phase and phosphate solutions solution as the second one. The chromatographic separation and the HG-AFS parameters were optimized by experimental design. The best results were obtained by using an elution program with 20 mmol l-1 EDTA + 2 mmol l-1 KHP solution at pH 4.5, during 1.15 min, then change to 50 mmol l-1 (NH4)2HPO4 solution at pH 8.3, switching back after 4.0 min to the first mobile phase, until 5 min, with a constant flow rate of 1.5 ml min-1. Retention time of Sb(V), Sb(III) and trimethylantimony species were 1.22, 2.31 and 3.45 min and the detection limits were 0.13; 0.07 and 0.13 μg l-1, respectively. Studies on the stability of this antimony species in sea water samples on the function of the elapsed time of storage in refrigerator at 4°C was performed employing the optimized method. Results revealed that Sb(III) is easily oxidized within some hours to Sb(V) in sea water stored at 4°C. However, when the sea water was immediately mixed with EDTA no oxidation of Sb(III) was observed up to 1 week of storage. The proposed methodology was then applied to the antimony speciation in sea water samples. © 2005 Elsevier B.V. All rights reserved.

Dates et versions

hal-01561327 , version 1 (12-07-2017)

Identifiants

Citer

I. de Gregori, W. Quiroz, H. Pinochet, Florence Pannier, M. Potin-Gautier. Simultaneous speciation analysis of Sb(III), Sb(V) and (CH 3)3SbCl2 by high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry detection (HPLC-HG-AFS): Application to antimony speciation in sea water. Journal of Chromatography A, 2005, 1091 (1-2), pp.94-101. ⟨10.1016/j.chroma.2005.07.060⟩. ⟨hal-01561327⟩

Collections

CNRS UNIV-PAU
23 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More